Requirements set out in resolution msc 191 79 ecdis equipment should meet the requirements of these standards and follow the relevant guidelines on ergonomic.
Ecdis power supply requirements.
The ecdis should be able to operate in a normal capacity even when it is connected and supplied by an emergency source of electrical power.
Power supply of the main ecdis.
V electrical power supply of the back up ecdis should be separated from electrical.
And vii connection cable for interface between main ecdis and back up ecdis shall be.
A second compliant ecdis which must be independent of the main ecdis and connected to the ships main and emergency power supply refer solas regulation chapter ii i.
Ultimately the purpose of the guideline is to ensure that an in.
The systems that may be acceptable could be a second ecdis unit using encs maintained by an independent power supply a chart radar a second ecdis unit using raster navigational charts rncs which are digital copies of paper charts maintained by an independent power.
For australian flagged ships you have two options to meet the back up requirements for ecdis.
Are acceptable as the requirements vary.
An ecdis system using encs with an independent power supply an appropriate folio of corrected up to date paper charts for the present voyage a raster chart display system rcds also known as an electronic chart system ecs using raster navigational charts rncs with an independent power supply.
5 4 when an ecdis is switched on following a switch off or power failure it should return.
Change over from one source of power supply to another including any interruptions in electrical supply should not require the equipment to be manually reinitialised for a period of 45 seconds.
Ups systems plc has a longstanding reputation for supplying marine approved ups units and can provide the widest range of options to back up critical onboard instruments and enable you to meet with imo rules.
Vi connection cables to gyro compass speed log and gps receiver shall be separated from.
Following the introduction of performance standards for electronic charts in 1995 the maritime safety committee msc the highest technical body of the international maritime organization imo adopted an amended chapter v safety of navigation of the international convention for the safety of life at sea solas.
An uninterruptible power supply ups provides backup in the event of power failure to ensure the ecdis can keep running smoothly.
Power supply it should be possible to operate ecdis and all equipment necessary for its normal functioning when supplied by an emergency source of electrical power in accordance with the appropriate requirements of chapter ii 1 of the 1974 solas convention.
It must also be connected to systems providing continuous position fixing.
Information system ecdis installation to determine if the ecdis meets the operational requirements defined by the international maritime organization imo.
Ecdis regulations solas regulations.