An electric strike must be used along with some other form of locking device such as a lockset or exit device panic bar.
Electric mortise lock vs electric strike.
Whether failsafe or failsecure controlled access and remote control.
For continuous recapture of a 1 deadbolt.
Electric cylindrical locks and mortise locks.
Electric strike magnetic locks 3 point locking mechanism securitech locks hi tower lock blumcraft lock.
Mortise locks operate almost entirely like a standard lock that most people have been conditioned to use all of their lives except they have a power cable connecting the lock to the power supply.
Hes 1006cas complete pac for deadbolt locks.
The electric strike lock is more secure in.
Electrified panic hardware rim mortise vertical rods electrified mortise.
This is also true of mortise locks but since mortise locks have a much more robust deadlocking feature it is not as much of an issue.
On doors with rim exit devices the latch is protected by the stop on the door frame.
Power supplies and electric power transfers will be needed for all of these locks to operate.
Electrified mortise locks wired mortise locks.
This leaves electrified panic hardware so let s finalize the selection.
Access control locks on doors have come a long way in the past 30 years or so.
Hes 9400 electric strike.
Hitower selectric and electra locksets provide both the locking and latching features required for fire rated doors to meet security needs and fire life safety code requirements.
Electric locks are used when additional security as well as added convenience are wanted at the opening.
With an electric strike the latch is much more exposed than with an electric lock making it a tempting target for tampering.
The low versatile profile cs series of electric strikes are designed for use with cylindrical locksets and select mortise locksets without deadbolt for both metal and wood door frames.
The slim line surface mounted solution for rim exit devices.
Electrified locks come in various types from bored locks mortise locks exit devices and magnetic locks some locks have more options than others.
Activation occurs with either the pressing of a panic bar from inside the building or when activated by an electronic key card or fob reader outside of the building.
The strongest most versatile electric strike available.
Building and fire life safety code compliant for fire rated office doors corridor doors lobby doors exit doors and stairwell doors.
Electrical power is supplied to the strike which holds the lock bolt in place keeping the door locked until the strike is activated by a buzzer keycard or other device.
These are an excellent option because they are incredibly easy to use and operate.
The fire rated concealed solution for mortise latchbolt locks.
An electric strike is a mechanically operated strike that releases a door when the mechanical part is activated.